Motic AE31 elite research grade inverted microscopes

The Motic AE31 Elite inverted microscopes provide excellent optical quality and unmatched operational convenience. The Colour Corrected Infinity Optical System (CCIS) allows new accessories and functions to be incorporated into the AE30/31 inverted microscopes at any time. The CCIS infinity design has succeeded in achieving longer working distances with higher Numerical Apertures (NA) representing a significant improvement in optical performance and versatility.Both OTP22439-10 AE31 Elite Binocular Inverted Microscope and OTP22439-12 AE31 Elite Trinocular Inverted Microscope include:WF10x/22 EyepiecesPlan Achromat PL4xPlan Achromat Phase 10x and 20x objectivesELWD condenserPhase sliderPH1 phase centring telescopePlain stage6V/30W Quartz illuminationMicroscope Stand:The design of the AE31 Elite series inverted ...

The Motic AE31 Elite inverted microscopes provide excellent optical quality and unmatched operational convenience. The Colour Corrected Infinity Optical System (CCIS) allows new accessories and functions to be incorporated into the AE30/31 inverted microscopes at any time. The CCIS infinity design has succeeded in achieving longer working distances with higher Numerical Apertures (NA) representing a significant improvement in optical performance and versatility.

Both OTP22439-10 AE31 Elite Binocular Inverted Microscope and OTP22439-12 AE31 Elite Trinocular Inverted Microscope include:

  • WF10x/22 Eyepieces
  • Plan Achromat PL4x
  • Plan Achromat Phase 10x and 20x objectives
  • ELWD condenser
  • Phase slider
  • PH1 phase centring telescope
  • Plain stage
  • 6V/30W Quartz illumination


Microscope Stand:

The design of the AE31 Elite series inverted microscopes has been optimised to integrate all functions enabling effective ergonomics and maximum expandability. The wide base provides strength and rigidity; furthermore the inverted "Y" support at the back on the base provides extra lateral stability. The size of the microscope is compact to minimize the footprint and conserve the limited desk space available in modern laboratories.

The ergonomic design of the AE31 Elite enables easy and stress-free operation. The coaxial coarse/fine focusing knobs, controls for the stage and light intensity, are placed conveniently at your finger tips to minimize fatigue.

Light Source:

The 6V/30W halogen Koehler illumination system provides bright, even illumination at any magnification. The "only-one-in-its°Class" centerable lamp is housed externally and has an externally operated control mechanism for all facets of illumination. A segmented illumination intensity indicator is ideally located for easy viewing.

An energy saving Auto-Off feature turns the instrument off if not used for 15 minutes. New Light Memory function, based on encoded five position nosepiece, will recall the last light intensity setup when changing ot a respective objective. Once set, there is no need to adjust the illumination when changing magnification.

Observation Tubes:

In order to maintain absolute parfocality, the Siedentopf eyepiece tubes will not change their length when interpupillary adjustments are made. The inclination of 45°for the binocular and trinocular tubes is chosen for comfort and posture management.

Trinocular version features professional light distribution slider for 100% binocular and 20/80% for binocular/photo. The trinocular heads are ideal for digital documentation and video projection.

Focusable Eyepieces:

A complete range of eyepieces and objectives are available to configure the AE31 Elite for your application. The standard Wide field 10x eyepieces for the AE31 Elite with an enlarged field of view of 22mm provides enlarged viewing fields for faster scanning and easier viewing. Parfocal focus is provided by independent diopter adjustment on each eyepiece. Users wearing eyeglasses will find the eyepieces' high eye point design very comfortable to use. Various graticules for measuring and counting are available for these eyepieces.

Quintuple Revolving Nosepiece:

The revolving left side facing nosepiece accepts five objectives. It runs on precision ball bearings and has internal positive click stops so that the image remains centred after each change in magnification. The internal components and the optics are sealed against fluid spills to ensure reliable and trouble-free usage. This allows the operator to concentrate fully on imaging the specimen and not to worry about accidentally damaging the microscope.

Objectives:

The CCIS objectives for inverted microscopes have long free working distances in comparison to normal objectives of the same magnification. The objectives are optically corrected to compensate for 1.1mm thick glass slides and provide easy routine operation. RMS thread.

Phase Contrast Microscopy:

Phase contrast is the most popular optical contrast method for viewing the detailed structure of unstained or living specimens. The Phase Plan Achromat objectives, coupled with the easy-to-operate phase slider, provide outstanding contrast for the most demanding applications. For a quick and easy change of magnification, Ph1 annular ring is provided on the centerable phase slider.

Condenser Mount:

The centerable condenser mount is height adjustable with rack and pinion and is dovetail mounted on the illuminating pillar with a solid clamp screw. The ELWD condenser with a numerical aperture of 0.30 and a working distance of 72mm is suitable for objectives of magnification from 4x - 40x with an aperture diaphragm in the bright field Koehler illumination and for phase contrast.

The phase annular ring Ph1 for 10x, 20x and 40x and Ph0 for 4x are centered by Allen Hex keys on the centerable slider.

Mechanical Stage and Accessories:

The standard stage is a fixed stage plate: the stage can be widened on both sides with auxiliary stage plates. A hard coating protects the stage surface from abrasion and wear. The tempered glass stage insert allows for checking the objective being used without removing the specimen from the stage.

An optional attachable mechanical stage with Well plate holder with low positioned coaxial controls is available. The mechanical stage also accepts interchangeable specimen holders for Petri dishes and glass slides.


Motic AE31 Elite Technical Specifications
Optical System Parfocal distance 45mm CCIS Optical System (Color Corrected Infinity System)
Observation tube Siedentopf 45°Binocular or Trinocular heads
Eyepiece Widefield WF 10x (FN22) with diopter adjustment
Nosepiece Quintuple reversed with splash protection
Coarse/Fine focusing Coaxially positioned control knobs, coarse 42mm/rotation, fine 0.2mm/rotation. Min. increment 2Micrometre. Coarse motion torque adjustable.
Stage Plain stage 200 x 260mm, hard coated surface.
Substage Illumination 6V/30W Quartz Halogen lamp in centerable housing and integrated diffuser
Condenser ELWD NA 0.30/72mm or LWD NA 0.50/28mm both focusable
Power Requirements Universal; 110-240V; 50/60Hz


Code Title Type Pack Size Availability Price Updated: 30-03-2024
OTP22439-10 Motic AE31 elite research grade inverted microscopes Binocular Each 3 weeks Quote only Quote
Quote
OTP22439-12 Motic AE31 elite research grade inverted microscopes Trinocular (80/20) Each 3 weeks Quote only Quote
Quote